2017 vExpert

I'm proud to announce that I've been selected as a 2017 vExpert !  Thanks for the recognition and congrats to all of the other vExperts, particularly my coworkers Jeff and Dennis !

Invalid VDS PortID Preventing vMotion

One of my customers had an issue where a bunch of VMs were not able to vMotion, despite the hosts being configured correctly in all regards (other VMs using the same VDS Port Groups, for example, could vMotion onto and off of the host where these VMs were running).  When DRS (or an administrator) attempted a vMotion, a generic "A general system error occurred: vim.fault.NotFound" error message would be displayed. When I took a look at these VMs, I noticed something interesting (besides the fact that they were all on the same host); their VDS Port numbers were universally high, like in the 5000s.  This was particularly interesting because when I looked at the VDS itself, the highest numbered port on it was 4378.  I supposed that these ephemeral ports had somehow been assigned invalid port numbers, which was causing vMotion to fail when the new destination was unable to reserve that invalid number on the VDS.  Interestingly, all of these VMs were communicating just...

PSODs and the iovDisableIR Setting

One of my customers recently came across an issue where their ESXi hosts were randomly crashing with a PSOD.  They had recently applied the latest SPP from HP and the latest ESXi 6.0 patches, and were now occasionally seeing these crashes with messages like "LINT1/NMI (motherboard nonmaskable interrupt), undiagnosed.  This may be a hardware problem..." As the PSOD implied, they had called HP support for help, but weren't making much progress.  I did some googling and found a really interesting blog post from Jason Whitelock about a recent ESXi update causing HP servers to PSOD .  He had come across the exact same issue and had tracked it down to the value of the iovDisableIR setting, which had changed in this latest ESXi update.  When he set it back to its original setting, the PSOD issue went away. As VMware explains it, Interrupt Remapping (the technology that's affected by this setting) enables more efficient IRQ routing and thus improves performance...

Using PowerCLI to get a Datastore from an NAA ID

This is just a quickie (mainly for my own notes in the future): if you ever need an easy way to figure out which datastore is being referenced by a given naa number (like if you're troubleshooting datastore access issues and the logs all reference that ID type), you can use this command to search it out: get-datastore | ? {$_.ExtensionData.Info.Vmfs.Extent.Diskname -match "NAA NUMBER"}

Creating VICredentialStore Items without Typing Your Password into the Command Line

I use PowerCLI a lot.  Like, when VMware said to stop using the C# client, I just started using PowerCLI instead of learning the Flash based web client.  As such, I log into many vCenter servers many times each day, and creating a VICredentialStore item for each vCenter that I use is one trick that saves me a lot of typing and therefore time. The New-VICredentialStoreItem cmdlet is super easy to use, which creates these credential store items.  Once you have an item created, those credentials get used automatically when you connect to a vCenter server, making the logon faster and easier.  To use it, just follow this syntax: New-VICredentialStoreItem -Host vCenterServer -User JColeman -Password SuperSecretPassword And there you go, next time you use connect-viserver vCenterServer , it will automatically pass JColeman  as the username and SuperSecretPassword  as the password. Of course, no one ever wants to do this.  Who in their right mind woul...

Extreme IO Latency Caused by a Poorly Seated Fiber Cable

One of my customers was experiencing some extreme IO latency in their environment: in the hundreds of ms.  Obviously, there was some pain associated with this issue, and so they asked for help.  This environment had 3 HP c7000 chassis and 2 different SANs; the issue was affecting every host accessing every LUN, so we decided that the issue must be in the fiber channel fabric somewhere. After poking around, we quickly realized that the firmware on the Brocade switches was from January 2013, so was quite old.  I pulled up top on each switch and saw no appreciable CPU or Memory usage.  Next, I looked at porterrshow to see if there were any problems on the switches; each one had a single port that had a ridiculous number of Enc Out errors.  I cleared the error stat counters by using portstatsclear -i 0-33 and then issued another porterrshow , and found that we had roughly 100,000 Enc Out errors on that port each second.  Coincidentally, each switch had 1 p...

Validating LUN Path Consistency via PowerCLI

One of my customers needed some help with making some zoning changes on their fiber switches after standing up a batch of new ESXi servers.  I already had a script to create 1:1 fiber channel zones on Brocade switches , so that part was easy, but zoning changes to an existing environment are a little scary.  As in, if you really mess it up, the storage is going to disappear and every VM is going to crash, scary.  Fortunately, you've got to really mess it up to cause an issue, and so this customer was willing to allow changes during business hours as long as we promised not to cause an outage ;) So, how can I enforce that promise?  Well, I've got my script to create accurate zones for the new hosts, but that's not really the dangerous part.  If that's messed up, it just means that the new hosts won't work... and since they're still being configured, they're obviously not in production yet.  The dangerous part is when you enable the new zones, in case you s...